KATEGORIE
Kategorie: Přepínače
3375 Kč
cena s DPH
Výrobce: D-Link; Třída produktu: SWITCH - administrovatelný; Síťová architektura: GigabitEthernet; SmartSwitch (WEB Managed): Ano; Počet portů 1000BaseT (RJ45): 24 ks; Počet slotů MiniGBIC (SFP): 4 ks; Management, monitoring a konfigurace: Administrace přes webové rozhraní, CLI - příkazový řádek, Telnet, TFTP - Trivial File Transfer Protocol, SNMP - Simple Network Management Protocol, Syslog - Security Issues in Network Event Logging; Autorizační protokoly a kontrola přístupu: ACL založen na MAC, ACL založen na IP a typu protokolu, IEEE 802.1x - Network Login, SSL - Secure Sockets Layer; Podporované protokoly a standardy: IEEE 802.3 - 10BaseT, IEEE 802.3u - 100BaseFX, IEEE 802.3ab - 1000BaseT, IEEE 802.3x - Flow Control, Auto MDI/MDI-X, IGMP - Internet Group Management Protocol, IEEE 802.1D - Spanning Tree, IEEE 802.1w - Rapid Convergence Spanning Tree, IEEE 802.3ad - Link Aggregation Control, IEEE 802.1Q - Virtual LANs, IEEE 802.1p - Priority, DHCP - Dynamic Host Configuration Protocol, ARP - Address Resolution Protocol, FE, GE, IPv4 - Internet Protocol version 4, IPv6 - Internet Protocol version 6; Velikost adresní tabulky MAC: 8000; Přepínací algoritmus: store-and-forward; Rychlost sběrnice: 56; Kapacita (propustnost): 41.7; Paměťový buffer: 1 MB; Vrstva (Layer) přepínání: 2; Možnost stohování: Ne; Typ počítačové skříně: 1U Rack; Maximální spotřeba energie: 17 Watt; Další funkce: port mirroring (zrcadlení portů); Šířka: 440 mm; Výška: 44 mm; Hloubka: 140 mm; Čistá hmotnost: 2.15 kg
1411 Kč
cena s DPH
D-Link DES-1005P 5-port 10/100 switch, 4x PoE+, 60W
D-Link DES-1005P (revize B1) je 5-portový 10/100M PoE switch bez managementu, jehož první čtyři porty podporují PoE+ napájení 802.3af/802.3at, tj. max. 30W na port. Celkový PoE výkon přepínače je 60W. Ze switche tak lze napájet až 4 PoE zařízení, jako jsou IP telefony, Wi-Fi přístupové body nebo IP kamery. Switch je bez větráků, s externím napájecím adaptérem, v kovovém provedení pro položení na poličku.
Specifikace:
• Provedení: desktop, na poličku
• 5x 10/100BASE-T porty RJ-45
• PoE+ 802.3af/802.3at napájení na portech č. 1-4, max. 30W na port
• Celkový POE výkon switche: 60W
• Automatické nastavení MDI/MDI-X na všech portech
• Standardy: IEEE 802.3 10BASE-T Ethernet (twisted-pair copper), IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper), ANSI/IEEE 802.3 NWay auto-negotiation, IEEE 802.3x flow control, IEEE 802.1p QoS
• Metoda přepínání: Store-and-forward
• Switching fabric: 1Gbps
• Forwarding rate: 0,744 Mpps
• MAC tabulka: 2K záznamů
• Vyrovnávací paměť (RAM Packet Buffer): 64 KB
• Rozměry: 100 x 98 x 28 mm
• Hmotnost: 0,26 kg
• Napájení: externí zdroj 53.5 V / 1.2 A (součástí dodávky)
• Spotřeba: 63,26W maximum (PoE on), 3,61W maximum (PoE off), 0,68 W (standby)
• Provozní teploty: 0°C až 40°C
• Provozní vlhkost: 0% až 95% relativní vlhkost, nekondenzující
21195 Kč
cena s DPH
TP-Link OMADA switch SG5428XMPP
Omada 24portový gigabitový stohovatelný switch Lite L3 se správou PoE++ a 4× 10G sloty
8× Gigabitové PoE++ porty 802.3af/at/bt (Max 90 W na port)
16× Gigabitové PoE+ porty 802.3af/at (Max 30 W na port)
4× 10Gb/s SFP+ sloty
Až 500 W celkový PoE rozpočet
Funkce Fast PoE a Perpetual PoE
Fyzické stohování až 4 jednotek pro vestavěnou redundanci a výkon
L3 funkce: RIP, OSPF, Statické směrování a DHCP server/relay
Bezpečnostní strategie: ACL, Port Security, DoS ochrana, 802.1X
ERPS podporuje rychlou ochranu a obnovení v kruhové topologii
Centralizovaná správa přes cloud pomocí Omada SDN kontroléru
Samostatná správa přes web, CLI, SNMP a RMON
Stránky produktu: https://www.omadanetworks.com/cz/business-networking/omada-switch-campus/sg5428xmpp
Technické specifikace
HARDWARE FEATURES
Interface • 24× 10/100/1000 Mbps RJ45 Ports (8× PoE++, 16× PoE+)
• 4× 1/10 Gbps SFP+ Slots**
• 1× USB 2.0 Port
• 1× RJ45 Console Port
• 1× USB Type-C Console Port
Fan Quantity 3
Power Supply 100-240 V~ 50/60 Hz
PoE Ports (RJ45) • Standard: 802.3af/at/bt compliant
• PoE++ Ports: Ports 1~8 (up to 90W per Port)
• PoE+ Ports: Ports 9~24 (up to 30W per Port)
• Power Budget: 500W*
• Fast PoE
• Perpetual PoE
Dimensions ( W x D x H ) 17.3 × 13.0 × 1.7 in (440 × 330 × 44 mm)
Mounting Rackmountable
Max. Power Consumption • 587.7 W (220V/50Hz) ( with 500 W PD connected @ 25 °C)
• 615.8 W (110V/60Hz) ( with 500 W PD connected @ 25 °C)
Max. Heat Dissipation • 2004.06 BTU/hr (220V/50Hz) ( with 500 W PD connected @ 25 °C)
• 2099.88 BTU/hr (110V/60Hz) ( with 550W PD connected @ 25 °C)
PERFORMANCE
Switching Capacity 128 Gbps per Unit
Stacking • Stacking Number: 4
• Stacking Port: 10G SFP+ Slot (uplink ports can be used as stacking ports)
• Stacking Bandwidth: Up to 40 Gbps (max 2 stacking ports)
Packet Forwarding Rate 95.23 Mpps
MAC Address Table 16 K
Packet Buffer Memory 12 Mbit
Jumbo Frame 9 KB
SOFTWARE FEATURES
Quality of Service • Class of Service
- 8 Queues of Priority
- Port Priority
- IEEE 802.1p Priority
- DSCP Priority
- Queue Min-Bandwidth
- Schedule Mode (SP, WRR, SP+WRR)
• Bandwidth Control
- Rate Limit
- Storm Control
• Voice VLAN
• User-Defined OUI
• Smoother Performance
• Action for Flows
- QoS remark (802.1P Remark, DSCP Remark)
L3 Features • IP Interfaces:
- IPv4: Max 128, IPv6: Max 128
• Static Routing
- IPv4 Max 512, IPv6: Max 128
• Host Route Table: Max 1,024 entries
• RIP: Version v1/v2, Max 1,796
• OSPF: Version v2/v3; v2: Max 1,796, v3: Max 450
• Static ARP: 512 static entries
• Dynamic ARP: 2,000 dynamic entries
• Proxy ARP
• DHCP Server:
- Max 64 IP Pools
- Max 1,000 Manual Binding Entries
• DHCP Relay:
- Relayed Interface
- Relayed VLAN
L2 and L2+ Features • Link Aggregation
• Spanning Tree Protocol
• Port-based and VLAN-based Loopback Detection
• 802.3x Flow Control
• ERPS
• Mirroring
• RSPAN
• MAC Address Table
• Multicast
- IGMP Snooping
- MLD Snooping
- L2 Multicast Table: Max 2,000
- Fast Leave
- Multicast VLAN Registration (MVR)
- Static Multicast Groups
- Multicast Filtering
Advanced Features • Automatic Device Discovery†
• Batch Configuration†
• Batch Firmware Upgrading†
• Intelligent Network Monitoring†
• Abnormal Event Warnings†
• Unified Configuration†
• Reboot Schedule†
ISP Features:
• 802.3ah Ethernet Link OAM
• L2PT (Layer 2 Protocol Tunneling)
• Device Link Detect Protocol (DLDP)
• DDM
• sFlow
VLAN • Max 4K VLAN Group (802.1q VLAN)
• 802.1Q Tagged VLAN
• MAC VLAN Entries: 60
• Multicast VLAN
• Management VLAN
• VLAN VPN (QinQ): Max 256 entries
• GVRP
• Protocol VLAN: Protocol Template 16, Protocol VLAN 12 entries
• Voice VLAN
• Private VLAN
Security • Port Isolation
• CPU-Defend
• ARP Inspection (Dynamic ARP Inspection)
• DoS Defend
• IP-MAC-Port Binding
-1,024 Entries
- DHCP Snooping
- ARP Inspection
- IPv4 Source Guard
• IPv6-MAC
-Port Binding
-1,024 Entries
- DHCPv6 Snooping
- ND Detection
- ND Snooping
- IPv6 Source Guard
• DHCP Filter
• Static/Dynamic Port Security
- Up to 64 MAC addresses per port
• Broadcast/Multicast/Unknown-unicast Storm Control
- kbps/ratio control mode
• 802.1X
- Port base authentication
- Mac base authentication
- VLAN Assignment
- MAB
- Guest VLAN
- RADIUS authentication and accountability support
• AAA (including TACACS+)
• Secure web management through HTTPS with SSLv3/TLS 1.2
• Secure Command Line Interface (CLI) management with SSHv2
• IP/Port/MAC-based access control
Management Features
Omada App Yes. Requiring the use of the Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller.
Centralized Management • Omada Cloud-Based Controller (Requires built-in version 5.15.22 or later)
• Omada Hardware Controller (Requires built-in version 5.15.20 or later)
• Omada Software Controller (Requires built-in version 5.15.20 or later)
Cloud Access Yes. Requiring the use of the Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller.
Zero-Touch Provisioning Yes. Requiring the use of the Omada Cloud-Based Controller.
Management Features • Web-based GUI
• Command Line Interface (CLI) through console port, telnet
• SNMPv1/v2c/v3
- Trap/Inform
- RMON (1, 2, 3, 9 groups)
• SDM Template
• DHCP/BOOTP Client
• 802.1ab LLDP/LLDP-MED
• DHCP Auto Install
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• Password Recovery
• SNTP
• System Log
• IEEE 802.3az Energy Efficient Ethernet (EEE)
OTHERS
Package Content • SG5428XMPP Switch
• Power Cord
• Console Cable
• Rackmount Kits
• Rubber Feet
• Quick Installation Guide
System Requirements Microsoft Windows 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC OS, NetWare, UNIX or Linux.
Environment • Operating Temperature: -5 °C to 40 °C (23 °F to 104 °F)
• Storage Temperature: -40 °C to 70 ? (-40 °F to 158 ?)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing
3416 Kč
cena s DPH
8portový gigabitový PoE inteligentný prepínač s 2 portami SFP - 8 x 10/100/1000Mb/s porty s automatickým vyjednávaním - 2 x 1000Mb/s porty SFP - pokročilé funkcie úspory energie, časovo riadené PoE - 802.3af a 802.3at, max. rozpočet PoE 65 W - Auto Surveillance VLAN - Konštrukcia bez ventilátorov - Half-/Full-Duplex, automatické vyjednávanie, Auto MDI/MDIX - IEEE 802.3x Flow Control - 802.3ad Link Aggregation - Asymetrická VLAN, Auto Voice VLAN - LLDP/LLDP-MED - 802.1p prioritné fronty - filtrovanie MAC/IP - MAC/IP ACL - 802.1X riadenie prístupu na báze portov, zabezpečenie portov - statické smerovanie a predvolená trasa - D-Link Safeguard Engine - sieťový asistent, webová správa, kompaktné CLI - podpora D-View, RMON - kompaktný 13" stolový kryt - firmvér verzie 7 nie je spätne kompatibilný s hardvérovou verziou D1/D2.
18369 Kč
cena s DPH
XGS2220-54, L3 Access Switch, 24x1G RJ45 2x10mG RJ45, 4x10G SFP+ Uplink, incl. 1 yr NebulaFlex Pro
2000 Kč
cena s DPH
Zyxel XMG-105 5 Ports 2,5G + 1 SFP+ MultiGig unmanaged Desktop Switch
591 Kč
cena s DPH
Výkonný a energeticky úsporný switch: Přepínač je vybaven 5 porty, ke kterým bez problému připojíte nejrůznější síťová zařízení všech rychlostí: 10, 100 i 1000 Mbit/s. Okamžitý přehled o stavu připojení a rychlosti získáte pomocí indikačních LED diod.
1483 Kč
cena s DPH
Gigabitový 16ti portový switch TEG1016G výrobce Tenda Technology, plně podporuje standardy IEEE 802.3, 802.3u, 802.3x, 802.3ab a je určený pro použití ve firmách i domácnostech.
Tenda TEG1016G přepíná data v síti pomocí 16ti portů RJ45 s přenosovou rychlostí 10/100/1000 Mb/s a automatickou detekcí rychlosti. Maximální propustnost je 32 Gb/s. Auto MDI/MDIX na každém z portů. Přepojování uzlů v režimu Store-and-Forward. Full-duplex kontrola toku 802.3x.
Switch je napájen interním zdrojem. Maximální spotřeba 12 Watt. Montáž do rozvaděče nebo na stěnu, kovové provedení.
Součástí balení je český a slovenský manuál.
Technické parametry
Standarty: IEEE 802.3, 802.3u, 802.3x, 802.3ab
Způsob ovládání: bez managementu
LED indikace: 16x Linka/Aktivita, 1x Napájení
Počet RJ45 10/100/1000 Mb/s portů: 16
Celková propustnost: 32 Gb/s
Velikost tabulky MAC adresace: 8K
Ochrana proti přepětí: 6kV
Level přepěťové ochrany: - pro porty: 6kV, - pro napájení: 6kV, ESD: vzduch: ±10kV, kontakt: ±8kV
MAC address learning: Auto learning & auto aging
Protokol: CDMA/CD
Store-and-Forward: ano
Montáž do rozvaděče: ano
Montáž na stěnu: ano
Materiál obalu: kov
Zdroj napájení: interní
Parametry napájení: 100-240V AC, 50/60 Hz
Spotřeba: max. 12 Watt
Rozměry: 440 × 179 × 44 mm
Provozní teplota: 0° až 45 °C
Chlazení, ventilátory: pasivní, bez ventilátorů, fanless
Obsah balení
1x Tenda TEG1016G
1x Stručná instalační příručka (CZ, SK, PL)
1x Napájecí kabel
1170 Kč
cena s DPH
KARTA ADAPTÉRU StarTech U.3 TO PCIE
Kategorie zboží: Příslušenství pro pouzdra a komponenty
12625 Kč
cena s DPH
Switch: Ano
Velikost switche: 1U
Podporovaný datový přenos:
*LAN 100M / 10 G
*SFP 10 G
Podporující síťové standardy:
*IEEE 802.1p
*IEEE 802.3
*IEEE 802.3ab
*IEEE 802.3ae
*IEEE 802.3an
*
7274 Kč
cena s DPH
Cisco switch CBS350-16P-E-2G-EU - REFRESH
CISCO REFRESH jsou repasované produkty, které společnost CISCO dodává s certifikací kvality, zárukou a servisní podporou odpovídající ekvivalentnímu novému produktu
Řízené switche řady Cisco Business 350 jsou spolehlivými stavebními prvky pro sítě malých firem. Díky intuitivnímu ovládacímu panelu, pokročilým funkcím a všudypřítomnému zabezpečení urychlují spravované switche řady Cisco Business 350 vaši digitální transformaci.
Záruka platná do End of Support 31. 10. 2029.
Oznámení End of Life pro CISCO CBS350
Stránky produktu: CBS350-16P-E-2G-EU
Quick start guide: Quick start guide
Switching capacity and forwarding rate (All switches are wire speed and nonblocking) Capacity in Millions of Packets per Second (mpps) (64-byte packets) 26,78
Switching Capacity in Gigabits per Second (Gbps) 36
Layer 2 switching Spanning Tree Protocol (STP) Standard 802.1d Spanning Tree support
Fast convergence using 802.1w (Rapid Spanning Tree [RSTP]), enabled by default
Multiple Spanning Tree instances using 802.1s (MSTP); 8 instances are supported
Per-VLAN Spanning Tree Plus (PVST+) and Rapid PVST+ (RPVST+); 126 instances are supported
Port grouping/link aggregation Support for IEEE 802.3ad Link Aggregation Control Protocol (LACP)
Up to 8 groups
Up to 8 ports per group with 16 candidate ports for each (dynamic) 802.3ad link aggregation
VLAN Support for up to 4,094 VLANs simultaneously
Port-based and 802.1Q tag-based VLANs; MAC-based VLAN; protocol-based VLAN; IP subnet-based VLAN
Management VLAN
Private VLAN with promiscuous, isolated, and community port
Private VLAN Edge (PVE), also known as protected ports, with multiple uplinks
Guest VLAN, unauthenticated VLAN
Dynamic VLAN assignment via RADIUS server along with 802.1x client authentication
CPE VLAN
Voice VLAN Voice traffic is automatically assigned to a voice-specific VLAN and treated with appropriate levels of QoS. Voice Services Discovery Protocol (VSDP) delivers network wide zero-touch deployment of voice endpoints and call control devices
Multicast TV VLAN Multicast TV VLAN allows the single multicast VLAN to be shared in the network while subscribers remain in separate VLANs. This feature is also known as Multicast VLAN Registration (MVR)
VLAN Translation Support for VLAN One-to-One Mapping. In VLAN One-to-One Mapping, on an edge interface customer VLANs (C-VLANs) are mapped to service provider VLANs (S-VLANs) and the original C-VLAN tags are replaced by the specified S-VLAN
Q-in-Q VLANs transparently cross a service provider network while isolating traffic among customers
Selective Q-in-Q Selective Q-in-Q is an enhancement to the basic Q-in-Q feature and provides, per edge interface, multiple mappings of different C-VLANs to separate S-VLANs
Selective Q-in-Q also allows configuring of Ethertype (Tag Protocol Identifier [TPID]) of the S-VLAN tag
Layer 2 protocol tunneling over Q-in-Q is also supported
Generic VLAN Registration Protocol (GVRP)/Generic Attribute Registration Protocol (GARP) Generic VLAN Registration Protocol (GVRP) and Generic Attribute Registration Protocol (GARP) enable automatic propagation and configuration of VLANs in a bridged domain
Unidirectional Link Detection (UDLD) UDLD monitors physical connection to detect unidirectional links caused by incorrect wiring or cable/port faults to prevent forwarding loops and black holing of traffic in switched networks
Dynamic Host Configuration Protocol (DHCP) Relay at Layer 2 Relay of DHCP traffic to DHCP server in different VLAN; works with DHCP Option 82
Internet Group Management Protocol (IGMP) versions 1, 2, and 3 snooping IGMP limits bandwidth-intensive multicast traffic to only the requesters; supports 2K multicast groups (source-specific multicasting is also supported)
IGMP Querier IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router
IGMP proxy The IGMP proxy provides a mechanism for multicast forwarding based on IGMP membership information without the need for more complicated multicast routing protocols.
Head-of-Line (HOL) blocking HOL blocking prevention
Loopback Detection Loopback detection provides protection against loops by transmitting loop protocol packets out of ports on which loop protection has been enabled. It operates independently of STP
Layer 3 IPv4 routing Wirespeed routing of IPv4 packets
Up to 990 static routes and up to 128 IP interfaces
IPv6 routing Wirespeed routing of IPv6 packets
Layer 3 Interface Configuration of Layer 3 interface on physical port, Link Aggregation (LAG), VLAN interface, or loopback interface
Classless Interdomain Routing (CIDR) Support for classless interdomain routing
RIP v2 Support for Routing Information Protocol version 2 for dynamic routing
Policy-Based Routing (PBR) Flexible routing control to direct packets to different next hop based on IPv4 or IPv6 Access Control List (ACL)
DHCP Server Switch functions as an IPv4 DHCP server serving IP addresses for multiple DHCP pools/scopes
Support for DHCP options
DHCP relay at Layer 3 Relay of DHCP traffic across IP domains
User Datagram Protocol (UDP) relay Relay of broadcast information across Layer 3 domains for application discovery or relaying of Bootstrap Protocol (BOOTP)/DHCP packets
Security ecure Shell (SSH) Protocol SSH is a secure replacement for Telnet traffic. Secure Copy Protocol (SCP) also uses SSH. SSH v1 and v2 are supported
Secure Sockets Layer (SSL) SSL support: Encrypts all HTTPS traffic, allowing highly secure access to the browser-based management GUI in the switch
IEEE 802.1X (Authenticator role) 802.1X: Remote Authentication Dial-In User Service (RADIUS) authentication and accounting, MD5 hash; guest VLAN; unauthenticated VLAN, single/multiple host mode and single/multiple sessions
Supports time-based 802.1X; dynamic VLAN assignment; MAC authentication
IEEE 802.1X supplicant A switch can be configured to act as a supplicant to another switch. This enables extended secure access in areas outside the wiring closet (such as conference rooms)
Web-based authentication Web-based authentication provides network admission control through web browser to any host devices and operating systems
STP Bridge Protocol Data Unit (BPDU) Guard A security mechanism to protect the network from invalid configurations. A port enabled for BPDU Guard is shut down if a BPDU message is received on that port. This avoids accidental topology loops
STP Root Guard This prevents edge devices not in the network administrator’s control from becoming Spanning Tree Protocol root nodes
STP loopback guard Provides additional protection against Layer 2 forwarding loops (STP loops)
DHCP snooping Filters out DHCP messages with unregistered IP addresses and/or from unexpected or untrusted interfaces. This prevents rogue devices from behaving as DHCP Servers.
IP Source Guard (IPSG) When IP Source Guard is enabled at a port, the switch filters out IP packets received from the port if the source IP addresses of the packets have not been statically configured or dynamically learned from DHCP snooping. This prevents IP address spoofing.
Dynamic ARP Inspection (DAI) The switch discards ARP packets from a port if there are no static or dynamic IP/MAC bindings or if there is a discrepancy between the source or destination addresses in the ARP packet. This prevents man-in-the-middle attacks.
IP/MAC/Port Binding (IPMB) The preceding features (DHCP Snooping, IP Source Guard, and Dynamic ARP Inspection) work together to prevent DOS attacks in the network, thereby increasing network availability
Secure Core Technology (SCT) Makes sure that the switch wi
548 Kč
cena s DPH
ML-S+2733-10 je singlemode 10G SFP+ WDM modul pro přenos dat pomocí jednoho vlákna s jedním LC konektorem. Vlnová délka (Tx/Rx) tohoto modulu je 1270/1330nm a je vhodný pro spojení až na vzdálenost 10km. Modul je "cisco compatibile" a je kompatibilní témě
32741 Kč
cena s DPH
TP-Link OMADA switch SX3832
Omada 24portový 10GBASE-T L2+ řízený switch s 8 sloty 10GE SFP+
24× 1/2,5/5/10 Gb/s porty RJ45
8× 1/10 Gb/s sloty SFP+
Přepínací kapacita 640 Gb/s
Centralizovaná cloudová správa prostřednictvím webu nebo aplikace Omada
Samostatná správa přes web, CLI, SNMP a RMON
Statický routing pomáhá směrovat interní provoz pro vyšší efektivitu.
VLAN, ACL, QoS, IGMP Snooping, OAM a DDM
ERPS podporuje rychlou ochranu a obnovu v kruhové topologii.
Odolné kovové pouzdro a konstrukce pro montáž do racku
Více informací o Omada Cloud SDN>?
Více informací o 10G multi-gigabitové technologii TP-Link >
Stránky produktu: https://www.omadanetworks.com/cz/business-networking/omada-switch-l3-l2-managed/sx3832
Technické specifikace
HARDWARE FEATURES
Interface • 24× 100Mbps/1Gbps/2.5Gbps/5Gbps/10Gbps RJ45 Ports (Auto-Negotiation/Auto MDI/MDIX)
• 8× 1/10G SFP+ Slots**
• 1× RJ45 Console Port
• 1× USB Type C Console Port
Fan Quantity 2
Physical Security Lock ?
Power Supply 100-240 V AC~50/60 Hz
Dimensions ( W x D x H ) 17.3×8.7×1.7 in (440×220×44 mm)
Mounting Rack Mountable
Max Power Consumption 104.9 W (@110V/60Hz)
106.5 W (@220V/50Hz)
Max Heat Dissipation 357.81 BTU/hr (@110 V/60 Hz)
363.23 BTU/hr (@220 V/50 Hz)
PERFORMANCE
Switching Capacity 640 Gbps
Packet Forwarding Rate 240 Mpps
MAC Address Table 32 K
Packet Buffer Memory 24 Mbit
Jumbo Frame 9 KB
SOFTWARE FEATURES
Quality of Service • 8 priority queues
• 802.1p CoS/DSCP priority
• Queue scheduling: SP (Strict Priority), WRR (Weighted Round Robin), SP+WRR
• Bandwidth Control: Port/Flow-based Rating Limiting
• Smoother Performance
• Action for Flows: QoS remark (802.1P Remark, DSCP Remark)
L2 and L2+ Features • 128 IP Interfaces: Support IPv4/IPv6 Interface
• Static Routing: 48 IPv4/IPv6 Static Routes
• Static ARP: 128 static entries
• 510 ARP Entries
• Proxy ARP
• Gratuitous ARP
• DHCP Server
• DHCP Relay: DHCP Interface Relay, DHCP VLAN Relay
• DHCP L2 Relay
• Link Aggregation
• Spanning Tree Protocol
• Loopback Detection
• 802.3x Flow Control
• Mirroring
L2 Multicast • Supports 4,000 (IPv4, IPv6) IGMP groups
• IGMP Snooping
• IGMP Authentication
• Multicast VLAN Registration (MVR)
• MLD Snooping
• Multicast Filtering: 256 profiles and 16 entries per profile
Advanced Features • Automatic Device Discovery†
• Batch Configuration†
• Batch Firmware Upgrading†
• Intelligent Network Monitoring†
• Abnormal Event Warnings†
• Unified Configuration†
• Reboot Schedule†
ISP Features:
• L2PT (Layer 2 Protocol Tunneling)
• Device Link Detect Protocol (DLDP)
• PPPoE ID Insertion
• ERPS
• 802.3ah Ethernet Link OAM
• DDM
VLAN • VLAN Group: Max 4K VLAN Groups
• 802.1q Tagged VLAN
• MAC VLAN: 256 Entries
• Protocol VLAN: Protocol Template 16, Protocol VLAN 12
• Private VLAN
• GVRP
• VLAN VPN: VLAN Mapping, VLAN Replace
• Voice VLAN
Access Control List • Time-based ACL
• MAC ACL: Source MAC, Destination MAC, VLAN ID, User Priority, Ether Type
• IP ACL: Source IP, Destination IP, Fragment, IP Protocol, TCP Flag, TCP/UDP Port, DSCP/IP TOS
• Combined ACL
• Packet Content ACL
• IPv6 ACL
• Policy: Mirroring, Redirect, Rate Limit, QoS Remark
• ACL applies to Port/VLAN
Security • IP-MAC-Port Binding
- 512 Entries
- DHCP Snooping
- ARP Inspection
- IPv4 Source Guard: 96 Entries
• IPv6-MAC-Port Binding
- 512 Entries
- DHCPv6 Snooping
- ND Detection
- ND Snooping
- IPv6 Source Guard: 95 Entries
• DoS Defend
• DHCP Filter
• Static/Dynamic Port Security: Up to 64 MAC addresses per port
• Broadcast/Multicast/Unicast Storm Control: kbps/ratio control mode
• 802.1X
- Port-based authentication
- Mac-base authentication
- VLAN Assignment
- MAB
- Guest VLAN
- Radius authentication and accountability support
• AAA (including TACACS+)
• Port Isolation
• Secure web management through HTTPS with SSLv3/TLS 1.2
• Secure Command Line Interface (CLI) management with SSHv1/SSHv2
• IP/Port/MAC-based access control
IPv6 • IPv6 Dual IPv4/IPv6
• Multicast Listener Discovery (MLD) Snooping
• IPv6 ACL
• IPv6 Interface
• Static IPv6 Routing
• IPv6 neighbor discovery (ND)
• Path maximum transmission unit (MTU) discovery
• Internet Control Message Protocol (ICMP) version 6
• TCPv6/UDPv6
• IPv6 applications: DHCPv6 Client, Ping6, Tracert6, Telnet (v6), IPv6 SNMP, IPv6 SSH, IPv6 SSL, Http/Https, IPv6 TFTP
MIBs • MIB II (RFC1213)
• Interface MIB (RFC2233)
• Ethernet Interface MIB (RFC1643)
• Bridge MIB (RFC1493)
• P/Q-Bridge MIB (RFC2674)
• RMON MIB (RFC2819)
• RMON2 MIB (RFC2021)
• Radius Accounting Client MIB (RFC2620)
• Radius Authentication Client MIB (RFC2618)
• Remote Ping, Traceroute MIB (RFC2925)
• Support TP-Link private MIB
MANAGEMENT
Omada App Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller.
Centralized Management • Omada Cloud-Based Controller
• Omada Hardware Controller
• Omada Software Controller
Cloud Access Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller.
Zero-Touch Provisioning Yes. Requiring the use of Omada Cloud-Based Controller.
Management Features • Web-based GUI
• Command Line Interface (CLI) through the console port, telnet
• SNMP v1/v2c/v3: Trap/Inform, RMON (1,2,3,9 groups)
• SDM Template
• DHCP/BOOTP Client
• 802.1ab LLDP/LLDP-MED
• DHCP AutoInstall
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• IEEE 802.3az Energy Efficient Ethernet (EEE)
• Password Recovery
• SNTP
• System Log
OTHERS
Certification CE, FCC, RoHS
Package Contents • SX3832 Switch
• Power Cord
• Console Cable
• Quick Installation Guide
• Rackmount Kit
• Rubber Feet
System Requirements Microsoft Windows 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC OS, NetWare, UNIX or Linux.
Environment • Operating Temperature: -5–50 ? (23–122 ?);
• Storage Temperature: -40–70 ? (-40–158 ?)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing
6296 Kč
cena s DPH
Inteligentné PoE+ napája viac zariadení Modely PoE (8HP/10HP/24EP/24HPv2/48HPv2) sa dodávajú s predvoleným režimom spotreby PoE, ktorý dodáva len skutočný výkon potrebný pre vaše sieťové zariadenia, zvyšok si vyhradzuje a optimalizuje svoj rozpočet energie. To znamená, že jeden prepínač môže napájať viac prístupových bodov, IP kamier a telefónov VoIP, čím sa zabezpečí lepšia návratnosť investícií pre vašu firmu. Všetky podporujú štandard IEEE 802.3at, ktorý poskytuje maximálne 30 W na port. 330 x 230 x 44 mm.